Biometra TOne Thermal Cyclers (2024)

Biometra TOne - Optimal Amplification Performance

  • Optimal price – performance ratio
  • Fast Ramping, Best Accuracy: Superior sample block temperature control
  • Whisper Quiet: Low noise emission of max. 45 dB
  • High Performance Smart Lid: Defined pressure control for highly reproducible results
  • Linear Gradient Tool: For easy gradient programming using the primer annealing temperature

Uniting Versatility and High Performance
Fast Ramping: Thanks to the new electronics, the Biometra TOne can reach high heating and cooling rates of up to 4°C/sec. Block Control: The Biometra TOne controls the sample block temperature without under- or overshooting the programmed target temperature. This reflects our philosophy that the instrument does exactly what the user has programmed it to do. The ingenious temperature control system incorporated into our RAC (Ramping – Accuracy – Control) technology maximizes experimental reproducibility and achieves outstanding temperature control accuracy.

The perfect block seal
The sample block is also perfectly sealed to prevent condensation from coming into contact with either the peltier elements located below the sample block or with other electronic components. The seal protects the peltier elements and extends the lifetime of the instrument.

Each Detail Matters
Whisper Quiet: The airflow of the Biometra TOne thermal cycler has been optimized to keep the maximum noise level of the instrument down to extremely low 45 decibels. This efficient airflow system also means that the Biometra TOne takes up very little space. At 26 x 43 centimeters, the dimensions of the unit would appear to be average at first glance – its effective footprint, however, also has to include the clearance zone needed to accommodate sufficient airflow at the back of the instrument. The efficient airflow of the Biometra TOne keeps this additional space requirement down to just ten centimeters – much lower than that of other thermal cyclers. A combination of low noise and a minimal footprint, Whisper Quiet technology is the result of 25 years of thermal cycler development experience.

High-Performance Smart Lid (HPSL)
The heated lid of the Biometra TOne is equipped with HPSL technology. An integrated slip clutch always maintains constant contact pressure, regardless of the shape and height of the plastic ware. This optimizes the contact between the sample block well and the walls of the plastic ware, resulting in reproducible conditions. As soon as the heated lid is closed, a rubber seal on the lid encapsulates the space surrounding the sample block. This closed space increases the sample block temperature uniformity and prevents condensation formation during the final PCR cooling step.

Automatic lid-opening mechanism
The Biometra TOne comes with an one-touch opening mechanism – just press the locking mechanism, and the heated lid opens. A spring mechanism holds the lid in the open position, preventing it from dropping down. The locking mechanism automatically engages when the operator closes the lid.

Easy Programming and Intuitive Handling
The intelligent way to program a gradient: Determining the optimum annealing temperature is a challenge when creating a new primer pair. Using the gradient tool allows the operator to find the optimum annealing temperature under experimental conditions and apply that temperature value to routine applications. Programming gradients usually means to set temperature for the first and the last row to determine the gradient range. For most thermal cyclers, the temperature interval is not the same from one row of the sample block to the next. In addition, the sigmoidal temperature curve of the gradient brings two disadvantages:

  1. The automatically resulting temperatures for the other rows of the sample blocks, in particular in its center, are almost always odd-numbered.
  2. The temperature differences between the rows are unevenly distributed, increasing towards the center of the sample block.

The Linear Gradient Tool (LGT) enables programming of a temperature gradient with defined temperature intervals (increment) between the individual rows of the sample block. It allows the user to enter the calculated Tm value minus, e.g., 5°C and the desired temperature increment (e.g. ± 1°C) between the rows of the sample block. For maximum comfort, the Linear Gradient Tool now supports programming of even-numbered temperature values for a maximum number of rows.

Pre-installed program templates
The Biometra TOne software offers a number of preinstalled program templates for different applications. The program templates provide a general protocol structure and can be easily adapted for the current experiment.

Multi-step programming
Editing a template or setup of new protocols is quite simple due to the multi-step programming feature, which allows users to enter all of the parameters for every program step within a single screen. Thus the multi-step programming renders constantly switching back and forth between different screens unnecessary and enables to change easily from step to step.

Biometra TOne Thermal Cyclers (2024)

FAQs

What temperature should a thermal cycler cover be? ›

Accessories SKU's
Product Specifications
Programmable lid temperature60° to 65°C, 100° to 115°C
Program memory200 complete programs
Temp. increments/decrementsYes
Time increments/decrementsYes
15 more rows

Is thermo the same as thermal cycler? ›

The thermal cycler (also known as a thermocycler, PCR machine or DNA amplifier) is a laboratory apparatus most commonly used to amplify segments of DNA via the polymerase chain reaction (PCR).

What is the purpose of the thermal cycler? ›

Thermal cyclers are designed to regulate heat transfer and deliver precise temperature control. The instrument can be fully programmed for each stage of a PCR protocol and multiple protocols stored for repeated use.

Why does the lid of the thermocycler need to be heated? ›

Similarly, a heated lid is a common feature of thermal cyclers to prevent evaporation and condensation of PCR samples during runs. Prior to the introduction of the heated lid, samples were overlaid with mineral oil to achieve the same purpose.

What is the best temperature for PCR? ›

The reaction temperature is raised to the optimal temperature of the enzyme for its maximal activity, which is generally 70–75°C for thermostable DNA polymerases.

Can you do PCR without a thermal cycler? ›

And, if you refuse to spend any money on a thermocycler, you can make one from a lightbulb and a fan. Moreover, if you have access to a 3D printer, you can make your own qPCR (real-time PCR) machine.

What is another name for a thermal cycler? ›

The Thermal Cycler (also known as a Thermocycler, PCR Machine or DNA Amplifier) is a laboratory apparatus used to amplify segments of DNA via the Polymerase Chain Reaction (PCR). The device has a thermal block with holes where tubes holding the PCR reaction mixtures can be inserted.

What is the lid temperature of PCR? ›

The purpose of keeping the lid temperature at 105C is to avoid the condensation of the water vapour generated from the PCR reaction mixture at 95C or 72C steps. Earlier version of PCR used to add mineral oil on top of the reaction mixture, so that evaporative loss was not there.

How do you calibrate a thermal cycler? ›

The calibration process involves measuring the temperature of the sample in different wells and comparing it to the reference thermometer. You can then adjust the settings of the thermal cycler accordingly.

What precautions should be taken when using a thermal cycler? ›

Never use abrasives, solvents or acid solutions that damage the external and internal part of your thermal cycler. If the thermal cycler has been attacked by external particles inside it has suffered spills, stop the protocol, disconnect, let cool, proceed with the maintenance method described.

How to decontaminate a thermal cycler? ›

The block and sample wells, trays, and the heat cover can be cleaned with a 10% bleach solution. This should be followed by the use of isopropanol or other appropriate alcohol to remove any sodium hypochlorite residue.

What are the three steps of the thermal cycler? ›

Three steps of PCR─denaturation, annealing, and extension─as shown in the first cycle, and the exponential amplification of target DNA with repeated cycling.

How much is a PCR machine? ›

PCR machines will vary in price, ranging from around $3,000 to above $15,000 with higher-end models. Browse the catalog of thermocyclers below across leading suppliers and submit a quote for more information, including cost, specifications, and more.

How much DNA do you need to start with to do PCR? ›

Template DNA

Nevertheless, the composition or complexity of the DNA contributes to optimal input amounts for PCR amplification. For example, 0.1–1 ng of plasmid DNA is sufficient, while 5–50 ng of gDNA may be required as a starting amount in a 50 µL PCR.

What temperature should a PCR lid be? ›

The purpose of keeping the lid temperature at 105C is to avoid the condensation of the water vapour generated from the PCR reaction mixture at 95C or 72C steps. Earlier version of PCR used to add mineral oil on top of the reaction mixture, so that evaporative loss was not there.

At what temperature should I wear thermals? ›

Wear thermals under daily clothes

You should check the indoor temperature when you wake up in the morning. If that temperature is lower than 18 degrees C, then, you should wear your thermals under a daily outfit.

What temperature should a thermal store be? ›

The thermal store is designed to work best when the store temperature is at or approaching 70°C – 75°C. While the thermal store can provide hot water at lower temperature storage, the available flow rates and volume will be reduced. Check the thermometer is showing the store temperature is at or approaching 70°C -75°C.

What is the temperature of thermal protector? ›

The temperature range of the Thermik PTCs lies between 70°C and 180°C. The main difference between PTC-thermistors and thermal protectors with bimetal system is that the PTCs require additional evaluation electronics to be functional. Higher and individual switching cycles are the advantages of the PTCs.

References

Top Articles
Latest Posts
Article information

Author: Kieth Sipes

Last Updated:

Views: 5522

Rating: 4.7 / 5 (67 voted)

Reviews: 90% of readers found this page helpful

Author information

Name: Kieth Sipes

Birthday: 2001-04-14

Address: Suite 492 62479 Champlin Loop, South Catrice, MS 57271

Phone: +9663362133320

Job: District Sales Analyst

Hobby: Digital arts, Dance, Ghost hunting, Worldbuilding, Kayaking, Table tennis, 3D printing

Introduction: My name is Kieth Sipes, I am a zany, rich, courageous, powerful, faithful, jolly, excited person who loves writing and wants to share my knowledge and understanding with you.